Your Harsh & Hazardous Area
Solutions Company

Sales and advice call or email +44 (0)1925 852745
sales@cablesystems.co.uk
Opening times: Mon - Thur 8am-5pm / Fri 8am - 3pm

  1. Trade Account
  2. Videos
  3. Downloads
  4. Contact
  5. News
  6. Basket
  7. Login
  8. Register
You are here
I.S Signal Converters
ACT20X-SDI-HDO-H-S
Weidmuller ACT20X-2HDI-2SDO-RNO-S

ACT20X-SDI-HDO-H-S Weidmuller

Part Number: 8965410000

Availability: Enquire about stock

ACT20X, EX signal isolating converter, 1-channel version, For ignition group IIB < 60 mA

£133.74 excl. VAT

ACT20X-SDI-HDO-H-S Details

Ex valve control modules, 60 mA ignition protection group IIB

1-channel valve control modules in 22.5 mm width with external power supply,

to control valves in Ex zones 0,1,2 from the safe zone.

The module comes with full three-way, 2.6 kV separation.

On the input side, NPN/PNP switching sensors can be connected.

On the output side, there are three 60 mA driver steps for ignition protection group IIB with

a minimum driver voltage of 9 V/11 V or 12.5 V available optionally.An additional alarm contact ("a" contact) reports status and error messages

The module can be configured using standard FDT/DTM software.

Supply voltage19.2 – 31.2 V DC
Type of connectionScrew connection, Removable terminal block
Power consumption< 2 W
Step response time10 ms
Protection degreeIP 20
Humidity0...95 % (no condensation)
ManufacturerWeidmuller
Product TypeValve control component

Ex valve control modules, 60 mA ignition protection group IIB

1-channel valve control modules in 22.5 mm width with external power supply,

to control valves in Ex areas zone 0,1,2 from the safe zone.

The module comes with full three-way, 2.6 kV separation.

On the input side, NPN/PNP switching sensors can be connected.

On the output side, there are three 60 mA driver steps for ignition protection group IIB with

a minimum driver voltage of 9 V/11 V or 12.5 V available optionally.

An additional alarm contact ("a" contact) reports status and error messages

The module can be configured using standard FDT/DTM software.

Add-on housing for TS35 DIN rail installation

Dimensions: L/W/H 119.2/ 22.5/ 113.6

Screw connection/ nominal cross-section 2.5 mm2Protection degree: IP20   input                         NPN, PNP switch signal                                       max. 28 VDC                                     output Ex                  Imax 60 mA @ ignition protection group IIB                                      U with load min. 9 V / min. 11 V / min. 12.5 V                                      U without load min. 24 V Alarm output relay 1 NO contact                                      250 VAC / 30 VDC @ 2A safe zone                                     32 VAC @ 0.5 A / 32 VDC @ 1 A zone 2Auxiliary power                   19 to 31.2 VDCPower loss approx. 1.8 W

Ambienttemperature range -20 °C to +60 °C                 

Secure isolation                   EN 61010, 3-way isolation up to 2.6 kV AC/DC of all circuits against each other

Working voltage                     300 V AC/DC at overvoltage category II and pollution degree 2

Approvals cULus, ATEX IECEX, FM

ATEX marking II 3 G Ex nA nC IIC T4

ATEX characteristic data U0  = 28 V DC

                                      I0  = 125 mA 

                                      P0 = 0.77 W

Type                                                           ACT20X-SDI-HDO-H-S

Recently viewed

You are here
I.S Signal Converters
ACT20X-SDI-HDO-H-S