eLLB 20 NIB
eLLB NIB

eLLB 20 NIB Eaton Crouse Hinds

Availability: Enquire about stock

Emergency Ex-Recessed Ceiling Light Fitting

POA excl. VAT

eLLB 20 NIB Details

eLLB 20... 18 - 58 W

Metallic design for Zone 1 and 21

The eLLB 20 explosion-protected ceiling light fitting with electronic ballast meet the requirements of ATEX-Directive 94/9/EC and are suitable for two-pin fluorescent lamps. These lamps are used for surface and flush mounting in ceilings, in particular in clean rooms where smooth, flush surfaces are very important. The area of application is in the pharmaceutical and chemical industry and in engineering as well as in paint shops and spraying cabinets. The housing comprises white-painted steel sheet with integrally moulded covering frame or, optionally, made of polished stainless steel. Safe installation in the ceiling is ensured with special fixing elements, who allows a universal and simple mounting in recessed clean room ceiling from 25 up to 90 mm thickness. In addition, it can also be fixed by means of two M8 drilled holes on the top of the housing. The hinged, frameless pane made of 6 mm thick safety glass is fixed with captive screws and has inside hinges. The sealing material is guaranteed silicone-leak-proof. 

The modern economical ballast EVG 09 according to the latest standards (IEC 60079-7: 2006) allows a safe and economical operation of bi-pin fluorescent lamps G13 according to IEC 60081. Lamps reaching its end of life will be monitored and securely switched off (EOL-effect). The high input voltage range allows international use. The standard two-channel structure means that if one lamp fails, the other one remains in operation. The standard two-sided through-wiring together with the generous terminal housing offers a cost-saving installation. 

The light switch is designed as an automatic disconnector pursuant to EN 60947-1 (IEC 60664) and reliably prevents the lamp from being switched on when the cover disc is open. With the optional CG-S module, single monitoring of the lamp is possible with the CEAG Emergency Light Supply Systems.

  • Two channel EVG with EOL monitoring as standard
  • Flush Installation Specially for Clean Rooms
  • Optionally in painted sheet steel or stainless steel
  • Safety locking due to integral automatic disconnector
  • High degree of protection IP66
  • Connection to CEAG Emergency Light Supply Systems possible
ManufacturerEaton Crouse Hinds