Speak to a team member +44 (0) 1925 852745
Home › Hazardous Area Products › Hazardous Area Lighting › Portable Hand Lamps › Eaton Crouse Hinds TX 20 & TX 40 LED Torchlight

Eaton Crouse Hinds TX 20 & TX 40 LED Torchlight

TX/CX 20/40 LED lighting system
(Zone 0, 1, 2, 21, 22)

Clear

Share this product:
One System – many possibilities

The TX/CX 20/40 LED lighting system is the ultimate, multifunc tio nal lighting solution for use in hazardous areas. Thanks to the im proved operating properties, the reduced maintenance requirements and the special features of an emergency lighting unit, this versatile lighting system is ideal for operation in almost all hazardous areas.

Lighting for Zone Zero

Safety first

The charger and the torch are continuously checked and any faults are indicated by means of an LED. The intelligent charging routine allows a gentle and optimum charging of the
battery, thus guaranteeing the high performance and long service life of the rechargeable batteries.

Maintenance-free and reliable

Based on the charging technique, the encapsulated design and the shockproof LED technique this maintenance free torchlights are constantly available.

More light

In spite of the low power requirement, the highly efficient and impact resistant LED lighting technology provides a very high luminous intensity. Together with a lens (5° TX 20,
4° TX 40) and the reflector, the 3W high efficiency LED produces a bright and uniform light flux (200lm TX 40, 114 lm TX 20), thus ensuring an optimum illumination of the work area.

Including Safety buffer

Before the overdischarge protection stage is reached, lamps automatically switches over to the weaker standby light which seriously extended the operating time.

Contact-free charging system

The charging system features an inductive coupling system. When plugged into the charger, the torch is contact-free char ged by induction. Thus, in sufficient contact and corrosion of the
contacts due to environmental influences are completely eliminated. More over, this technology also provides an enhanced protection of the system, which means that the charger can
be mounted and operated in Zone 1, while the torch can also be operated in Zone 0.

Safety lighting included

If the power supply of the charger fails, the emergency lighting function switches the torch in it on automatically – regardless of the position of the switch. Optionally, to ensure that the torch is always in its place, there is a seal point for securing the torch in the charger. Thus, this innovative lighting system can also act as an essential part of stationary safety installations.

Features

  • For hazardous areas zones 0, 1 and 2
  • Operating cycle ca. 5 hours
  • High light output due to 3 W power LED
  • Maintenance-free rechargeable battery
  • Emergency lighting function
  • Automatic standby light when battery capacity decreases
  • Inductive charger for Ex Zone 1
  • Automatic function test of lamp & charger
  • Deep-discharge protection
  • High degree of protection IP 67
Torchlight TX 20 Torchlight TX 40
EC-Type Examination Certificate DNV-11-ATEX-99371 DNV-2008-OLS-ATEX-38719
Marking to 94/9/EC D II 1 G Ex ia [op is] IIC T4 Ga D II 1 G Ex ia IIC T 3
IECEx Certificate of Conformity IECEx DNV 11.0009 IECEx DNV 08.0010
Permissible ambient temperature -40 °C up to 60 °C -40 °C up to 60 °C
Lamp high efficiency LED, 3 W high efficiency LED, 3 W
Luminous flux 114 lm 200 lm
Max. luminous intensity approx. 550 cd approx. 5,000 cd
Light aperture Polycarbonate with 5° lens/hardened
scratch resistant glass 3 mm
Polycarbonate with 4° lens/hardened
scratch resistant glass 3 mm
Indication lamps red and green LED red and green LED
Degree of protection accd. EN 60529 IP 67 IP 67
Enclosure material Plastic yellow/black Plastic yellow/black
Weight 0.13 kg 0.13 kg
Dimensions (LxWxH) 150 x 42 x 34 mm 230 x70 x 70 mm
Operating time approx. 5 h approx. 5 h
Operating life More than 1000 recharge cycles More than 1000 recharge cycles

Eaton Crouse Hinds TX 20 & TX 40 LED Torchlight Datasheet

Product Enquiry

  • This field is for validation purposes and should be left unchanged.