Speak to a team member +44 (0) 1925 852745
Home › Hazardous Area Products › Hazardous Area Cable Glands › Hazardous Location (Group II) › Capri ADE1FC Non-armoured Barrier Gland

Capri ADE1FC Non-armoured Barrier Gland

For use with non-armoured, armoured and tray cable, ADE-1FC Non-armoured Barrier Glands are installed:

  • To provide a flameproof and weatherproof seal on the outer sheath of the cable
  • To provide an explosion proof compound seal (denoted by red back nut) on conductor
Clear

Share this product:

Suitable for the following cable types

  • Non-armoured cable
  • Marine shipboard cable / P Type cable

Product Specification

Material:

Nickel-plated brass for superior corrosion resistance.

316 Stainless steel, bronze and aluminium options available.

It is recommended that a suitable lubricant is used on all threads of stainless steel and aluminium versions.

Operating Temperature:

TSC Compound: -60°C to +80°C

(for UL Marine certification refer to page 0)

Ingress Protection (IP):

Metric Threads:

Fitted on equipment with a flat surface, on threaded hole, or on blank hole (“d” use excluded) fixed by a qualified locknut with all threads engaged:

IP64 and IP66 without Sealing Washer and surface finish of Ra 0.4μm or on threaded hole and surface finish of Ra 1.6μm max.

IP64 and IP66 with all Sealing Washers (Red Fibre, Green Fibre, Neoprene, Nylon or PTFE) on surface Ra 6.3μm max.

IP68 tested 30m/7days with Red Fibre or Green Fibre Sealing Washers on surface Ra 6.3μm max.

NPT Threads:

IP64, 66 and IP68 tested 30m/7days, always fitted on equipment with threaded hole; HTL lubricant may be needed.

Clamping Technology:

Elastomeric seal on cable outer-sheath

Compound barrier seal on cable conductors

External cable clamping module optional

  • Standard material is nickel-plated brass for superior corrosion resistance
  • Provides a flameproof and weatherproof seal on outer sheath of cable
  • Provides explosionproof compound seal (denoted by red back nut) on conductors
  • Deluge boot provides enhanced protection from water ingress
  • TSC compound suitable for use in operating temperatures -60°C to +80°C (UL Marine -20°C to +40°C)
  • Available with metric or NPT threads
General
Protection Type Explosionproof
Gland Type Non-armoured barrier
Cable Type Non-armoured, tray, Type P and marine shipboard cable (does not terminate the armour)
Sizes 3/8″ to 4″ (NPT); M16 to M110 (Metric)
Environmental Rating NEMA 4X; IP66/IP68
Standard Material Nickel-plated brass
Optional Materials 316L stainless steel; bronze

Capri ADE-1FC Non-armoured Barrier Gland Datasheet

Product Enquiry

  • This field is for validation purposes and should be left unchanged.