Overview
‘T’ (type ATU) adaptors provide an opportunity for two cable entries using one equipment entry where pre-machine holes are limited, whilst maintaining Exd/Exe certifications. The ‘T’ adaptor may also be used to change threadform or to different sizes.
Redapt ‘T’ Adaptors are marked with the appropriate approval number and size.
Certifications and Compliances
Code of Protection Categories
ATEX: I M2 (not aluminium), Ex d IMb, Ex e I Mb or II GD, Ex d IIC Gb,
Ex e IIC Gb, Ex tb IIIC Db IP6X
IECEx: Ex d I Mb, Ex e I Mb (not aluminium), Ex d IIC Gb Ex e IIC Gb,
Ex tb IIIC Db IP6X
Compliance Standards
ATEX: EN 60079-0, EN 60079-1, EN 60079-7, EN60079-31
IECEx: IEC 60079-0, IEC 60079-1, IEC 60079-7, IEC 61241-1
Certificate Details
ATEX: Sira 10ATEX1056U, ITS16ATEX101340U
IECEx: IECEx SIR 10.0025U, IECEX ITS16.0015U
TEMPERATURE
The item is classified as a component and therefore metallic products are not
given an operating temperature range.
Ingress Protection (IP):
Independently tested to IP66 / IP68 when fitted in accordance to
manufacturer’s instructions.