Eaton Crouse Hinds Exit N LED Emergency Exit Sign

EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22

Clear

Share this product:
EXIT for Zone 1 and Zone 21 / Exit 2 for Zone 2 and Zone 22 – Moulded plastic version with LED-technology
Leading the way in hazardous areas

The EXIT series of explosion protected escape sign luminaires fulfills the requirements of ATEX Directive 2014/34/EU and EN 60598, Section 2.22 for emergency lighting luminaires. The luminaires are suited for marking escape routes and exits in hazardous areas.

Only white, high-efficiency LEDs are used as illuminants for these luminaires. This guarantees maintenance free operation, as the illuminants do not need replacing throughout the complete service life of the luminaire.

The supply electronics is also laid out for this service life; the LED circuits are intrinsically safe.

The wide input voltage range allows international use. The housing of these luminaires is made of high-grade polycarbonate: the escape signs comply with the latest standards.

Thanks to the robust design and high degree of protection, these luminaires are suited for both indoor and outdoor use.

As an emergency lighting luminaire with self-contained battery system for maintained operation, the EXIT N and the EXIT 2 N features an NC battery and automatic function monitoring
with operating time test.

With the optional built-in V-CG-S monitoring module with coding switch for max. 20 addresses, this luminaire can also be used as an individually monitored emergency lighting luminaire that is connected to a CEAG emergency lighting supply system. With this, the operator can programme the switching mode according to the respective requirements. Thus, as many as 20 luminaires with
different switching modes can be connected to one end circuit.

Features
  •  All-plastic polycarbonate housing
  •  Power-saving LED technology, maintenance-free throughout service life
  •  High degree of protection IP66
  •  Luminaire with self-contained battery unit and automatic function monitoring
  • Connection and monitoring with CEAG emergency lighting supply systems possible

For all types of application

The escape sign luminaires of the „EXIT“ series are available as mains luminaires “EXIT” and „EXIT 2“, e.g. for specially safeguarded industrial networks in production plants, as “EXIT
V-CG-S” and „EXIT 2 V-CG-S“ emergency lighting luminaires with individual function monitoring for use in CEAG emergency lighting supply systems, as well as “EXIT-N” and „EXIT 2 N“
emergency lighting luminaires with self-contained battery systems and automatic function and operating time tests.

Green light for all zones

On account of the robust, all-plastic polycarbonate housing in the high degree of protection IP66, the EXIT luminaire can be installed almost anywhere, both indoors and out. The luminaire
is designed in the type of protection Ex e m ib IIC up to T6 as well as Ex tb IIIC T80 °C and, in accordance with the ATEX Directive. It can be used in hazardous areas with explosive gas
atmospheres (Zones 1 and 2) and explosive dust atmospheres (Zones 21 and 22). The EXIT 2 series can be used in hazardous areas with explosive gas atmospheres (Zones 2) and explosive dust atmospheres (Zones 22).

Conformity to standards

The EXIT explosion-protected escape sign luminaire series fulfils the requirements of ATEX Directive 2014/34/EU and EN 60598, Part 2.22 for emergency lighting luminaires. It is suited
for marking escape routes and exits in potentially explosive atmospheres. The housing of this luminaire is made of high-grade polycarbonate and it goes without saying that the escape
signs comply with the latest standards.

Maintenance-free operation

The white LED technology used as the light source allows maintenance-free operation without replacement of the illuminant. The lighting values required for the escape sign are maintained
throughout the complete service life of the LEDs, namely approx. 50,000 hours. It goes without saying that the supply electronics are also designed for this extremely long operating time. This reduces operating costs and increases the operating safety considerably, in particular in locations that are difficult to access.

For international use

The LED escape sign luminaire of the EXIT series was designed to meet the requirements of a large number of different safety concepts. Thanks to the wide input voltage range from 110 V to 277 V AC and up to 250 V DC, this luminaire can be used internationally, whereby the supply circuits of the LED circuits are intrinsically safe.

The internationally valid certificate „IECEx“ enhances the scope of this light fitting.

The luminaire has a visibility range of 25 metres and it is available with a wide variety of pictograms, where country-specific solutions can be created without any problems.

Double safety

Whenever the operational safety of explosion- protected safety and escape sign luminaires is involved, there is no room for compromises, as only a luminaire that is fully functional at all times can save human lives. The new series of explosion-protected LED escape sign luminaires not only fulfils the extremely high explosion protection requirements, but it also fulfils the legal requirements for emergency and safety lighting installations. The new EXIT is capable of safely showing the right way to go at all times, even in complex and often badly laid out industrial installations with hazardous areas.

EXIT (Zone 1 & 21)EXIT N (Zone 2 & 22)
EC-Type Examination CertificateBVS 09 ATEX E 029BVS 09 ATEX E 029
IECEx Certificate of ConformityIECEx BVS 13.0017IECEx BVS 13.0017
Marking accd. to 2014/34/EUD II 2 G Ex e ib mb IIC T6/T5 Gb
D II 2 D Ex tb IIIC T80°C Db
D II 2 G Ex e ib mb IIC T5/T4 Gb
D II 2 D Ex tb IIIC T80°C Db“
Marking accd. to IECExEx e ib mb IIC T6/T5 Gb
Ex tb IIIC T80°C Db
Ex e ib mb IIC T5/T4 Gb
Ex tb IIIC T80°C Db
Permissible ambient temperature
specified data
-20 °C up to +40°C (T6)
-20 °C up to +50°C (T5)
-20 °C up to +40°C (T5)
-20 °C up to +50°C (T4)
+5 °C up to +35 °C
Battery12 V/800 mAh NC-Accu
Rated power consumptionapprox. 6 VAapprox. 10 VA
Rated voltage110 V – 277 V AC
110 V – 250 V DC
110 V – 277 V AC
110 V – 250 V DC
Rated voltage EXIT 24 V12 – 24 V DC (-15 % / + 20 %)
Rated current AC/DC220 V = 20 mA,
110 V = 40 mA
230 V ≃ 50 mA,
110 V ≃100 mA
FrequencyDC and 50 – 60 Hz (AC)DC and 50 – 60 Hz (AC)
Charging duration for capacity > 90 %24 h
Power factor cos ϕ≥ 0.95≃ 0.5
Circuitelectronic power supplyelectronic power supply
Protection classII
Viewing distance25 m25 m
Lamp / Illuminanthigh output-LEDs, whitehigh output-LEDs, white
Rated emergency lighting durationapprox. 3 h
Dimensions (L x W x H)356 x 175 x 76 mm356 x 175 x 76 mm
Connecting terminals3 x loop terminal 2.5 mm² 1)3 x loop terminal 2.5 mm² 1)
Enclosure colourgrey, RAL 7035grey, RAL 7035
Enclosure materialPolycarbonatePolycarbonate
Weight2 kg2.5 kg
Cable glands / gland plates /
enclosure drilling
1 x Ex-e cable glands
M20 x 1.5 (plastic) /
1 x Ex-e-screw plug M20 or
2 x M20 x1.5 metal thread,
1 x screw plug M20
1 x Ex-e cable glands
M20 x 1.5 (plastic) /
1 x Ex-e-screw plug M20 or
2 x M20 x1.5 metal thread,
1 x screw plug M20
Type of mountingwall mountingwall mounting
Degree of protection accd. to EN 60529IP66IP66
Protective cover / protective bowlPolycarbonatePolycarbonate
1) Option: 3 x 4 mm² screw terminals

CEAG Exit N LED Emergency Exit Sign Datasheet

Product Enquiry