Overview
Raxton Exe Earth Lead Adaptors (Type DG) allow for earth continuity to be maintained by providing an earth lead which can be terminated inside the enclosure. Earth Lead Adaptors are produced with an undercut and supplied complete with an ‘O’ring to maintain the IP integrity of the installation.
Earth Lead Adaptors are marked with the appropriate approval number and size. Raxton Exe Threaded Earth Plates are designed to ensure earth continuity when terminating brass glands into non-metallic enclosures. The additional use of a locknut is recommended to ensure pressure is maintained with the wall enclosure. Threaded Earth Plates are marked with the appropriate approval number and size.
Certifications and Compliances
Code of Protection Categories
ATEX: I M2, Ex e I Mb or II G D, Ex e IIC Gb, ExIIIC tb Db
IECEx: Ex e I/IIC Mb/Gb, Ex e I/IIC Mb/Gb, Ex IIIC tb Db
GOST: ExeIIU
INMETRO: Ex e IIC Gb, Ex tb IIIC IP66/67
Compliance Standards
ATEX / GOST: EN 60079-0, EN 60079-7, EN 60079-31
INMETRO: ABNT NBR IEC 60079-0, ABNT NBR IEC 60079-7,
ABNT NBR IEC 60079-31
IECEx: IEC 60079-0, IEC 60079-7, IEC 61241-1
Certificate Details
ATEX: Sira 10ATEX1225X, ITS16ATEX101336X
IECEx: IECEx SIR 12.0014X, IECEx ITS16.0011X
GOST: TC RUC-G B.ГБ06.B.00105
INMETRO: NCC 12.0764X
TEMPERATURE
The item is classified as a component and is therefore not given a
temperature rating. The O-ring has an operating temperature of
-30°C to +150°C.