CEAG eLLK/M Fluorescent Standard & Emergency

Standard & Emergency light fittings with a self-contained battery system for fluorescent lamps, for hazardous areas Zone 1, 2, 21 and 22

The eLLK 92018/18 & eLLK 92036/36 Standard fittings are LED ready

Clear

Share this product:
Ex-Emergency light fittings with a self-contained battery system for fluorescent lamps
If you need a reliable and decentralized emergency lighting

Emergency lighting luminaires with a self-contained battery system provide a decentralised solution for the mandatory emergency lighting, independent of central systems. In large plants, in particular, these luminaires offer significant cost benefits.

More safety due to sophisticated micro-electronics

Thanks to a new charging and monitoring technology with intelligent micro-electronics, the NE emergency lighting luminaires provide reliable safety and reduced maintenance costs. A function test lasting 5 minutes, that is carried out automatically on a weekly basis, even during mains operation, and a quarterly, partial duty-cycle test provide additional safety and drastically reduce the
necessary amount of manual tests. The charging and discharging functions are monitored constantly by the micro-processor and are indicated via a diode display. Only the spent energy is recharged – therefore, overcharging is not possible. The so-called memory effect cannot occur – the service life of the battery is optimized. The need to replace a battery, a fault in the emergency
lighting circuit or a faulty battery is indicated by the LED display. Due to a new type of battery connection, the battery can be replaced in the hazardous area. The emergency lighting cycle can be set locally for 1.5 or 3 hours. A remote switch inquiry is standard.

Maintenance possible even in hazardous areas

The battery is installed in a separate, certified housing and Ex-d connectors link the battery unit and the luminaire. After loosening the locking screws, the battery can be taken away, whereby
the Ex-d switching contact in the flameproof compartment is cut-off, thus disconnecting the battery circuit. As a result, the battery is cut off completely from the charging circuit of the luminaire and it can therefore, also be replaced in the hazardous area at every time. A detachable strap protects the insert from being dropped inadvertently.

Simple and cost-effective installation

In conjunction with the generously dimensioned terminal compartment, the standard single-ended through-wiring allows a cost-effective installation. The double-sided locking facility with 10 or 20 latch points allows the protective bowl to be hinged on both sides, meaning that the fitting can be mounted on either side.

International certification

Special versions according to the NEC standards are available for use on the American market. CSA certification for the types of luminaires eLLK 92 NE 2217 (2 x 17 W) and eLLK 92 NE
4232 (2 x 32 W) allows their use there. Other country-specific approvals, such as for Brazil or the new Eurasian Conformity (EAC) for placing them on the market in Russia, Belarus and Kazakhstan, are available.

Features
  • Standard dual channel ballast with EOL monitoring
  • Automatic weekly 5 minute function test
  • Automatic quarterly partial duty cycle test
  • LED display for indication of the charging, operation or fault status
  • Capacity-dependent charging of the battery
  • Easy replacement of battery, even in Ex-area
  • Double-sided central locking facility
  • Safety interlocking system due to an integrated forced isolating switch
  • Safety standard IP66
eLLK 92018/18 NE (2 x 18 W) eLLK 92036/36 NE (2 x 36 W)
EC-Type Examination Certificate BVS 09 ATEX E 034 BVS 09 ATEX E 034
IECEx Certificate of Conformity IECEx BVS 09.0033 IECEx BVS 09.0033
Marking accd. to 2014/34/EU D II 2G Ex db eb mb ib IIC T4 Gb
D II 2 D Ex tb IIIC T80 °C Db
D II 2G Ex db eb mb ib IIC T4 Gb
D II 2 D Ex tb IIIC T80 °C Db
Marking accd. to IECEx Ex de mb ib IIC T4 Gb
Ex tb IIIC T80 °C Db
Ex de mb ib IIC T4 Gb
Ex tb IIIC T80 °C Db
Permissible ambient temperature -25 °C up to +55 °C
(specified data: -5 °C up to +35 °C)
-25 °C up to +55 °C (220 – 254 V)
-25 °C up to +40 °C (120 V)
(specified data: -5 °C up to +35 °C)
IK-class according to IEC/EN 62262 IK 10 =^ 20 J IK 10 =^ 20 J
Rated voltage 120 – 254 V AC 220 – 254 V AC / optional 120 V AC
Rated current 0.23 A 0.4 A
Frequency 50 – 60 Hz 50 – 60 Hz
Charging duration ≥ 14 h ≥ 14 h
Power factor cos ϕ ≥ 0.95 ≥ 0.95
Circuit EVG with emergency lighting supply EVG with emergency lighting supply
Protection class I I
Lamp / Illuminant 2 x T26 / 18 W (T8) 2 x T26 / 36 W (T8)
Rated luminous flux 2700 lm 1) 6700 lm 1)
Lamp cap G13 accd. to IEC 60061-1 G13 accd. to IEC 60061-1
Light output ratio 78 % 78 %
Luminous flux in emergency operation
(1.5 h, one lamp)
1215 lm (90 %) 1507 lm (45 %)
Luminous flux in emergency operation
(3 h, one lamp)
607 lm (45 %) 837 lm (25 %)
Rated emergency lighting duration Lamps can be set on site for an
emergency lighting duration of 1.5 or 3 hours (single lamp)
Lamps can be set on site for an
emergency lighting duration of 1.5 or 3 hours (single lamp)
Dimensions (L x W x H) 900 x 188 x 130 mm 1500 x 188 x 130 mm
Connecting terminals L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal
Enclosure colour RAL 7035 light grey RAL 7035 light grey
Enclosure material glass-fibre reinforced polyester glass-fibre reinforced polyester
Weight 8.8 kg 12 kg
Cable glands / gland plates /
enclosure drilling
Ex-e cable glands M25 x 1.5 (plastic),
option: M20 x 1.5 metal thread 2)
Ex-e cable glands M25 x 1.5 (plastic),
option: M20 x 1.5 metal thread 2)
Degree of protection accd. to EN 60529 IP66 IP66
Protective cover / protective bowl Polycarbonate Polycarbonate
1) depends on used lamps
2) with dustcover if entry/thread is not closed
eLLM 92018/18 NE (2 x 18 W)
EC-Type Examination Certificate BVS 09 ATEX E 034
EC-Type Examination Certificate BVS 09 ATEX E 034
IECEx Certificate of Conformity
IECEx BVS 09.0033
Marking accd. to 2014/34/EU D II 2 G Ex de mb ib IIC T4
D II 2 D Ex tb IIIC T80 °C Db
Marking accd. to IECEx Ex de mb ib IIC T4 Gb
Ex tb IIIC T80 °C Db
Permissible ambient temperature -20 °C up to +55 °C
(specified data: -5 °C up to +35 °C)
IK-class according to IEC/EN 62262 IK 10 =^ 20 J
Rated voltage 120 – 254 V AC
Rated current 0.23 A
Frequency 50 – 60 Hz
Charging duration ≥ 14 h
Power factor cos ϕ ≥ 0.95
Circuit EVG with emergency lighting supply
Protection class I
Lamp / Illuminant 2 x T26 / 18 W (T8)
Rated luminous flux 2700 lm 1)
Lamp cap G13 accd. to IEC 60061-1
Light output ratio 78 %
Luminous flux in emergency operation
(1.5 h, one lamp)
1215 lm (90 %)
Luminous flux in emergency operation
(3 h, one lamp)
607 lm (45 %)
Rated emergency lighting duration Lamps can be set on site for an
emergency lighting duration of 1.5 or 3 hours (single lamp)
Dimensions (L x W x H) 1205 x 188 x 130 mm
Connecting terminals L1, L2, L3, L, N, PE; max. 2 x 6 mm2 per terminal
Enclosure colour RAL 7035 light grey
Enclosure material glass-fibre reinforced polyester
Weight 10.5 kg
Pole socket Ø 44 x 150 mm
Cable glands / gland plates /
enclosure drilling
Ex-e cable glands M25 x 1.5 (plastic)
Degree of protection accd. to EN 60529 IP66
Protective cover / protective bowl Polycarbonate
1) depends on used lamps

CEAG eLLK Fluorescent Standard & Emergency Datasheet